For construction grade spruce one of the most common floor joist species a common building code is that floor joists that support dead roof loads and live floor loads cannot be extended beyond 16 inches for 2 x 8.
Maximum floor joist cantilever code.
With the allowable cantilever of the joists this beam would support a deck 12 feet by 17 1 2 feet.
Cantilevered floor joists 1 floor joists supporting roof loads shall not be cantilevered more than 400 mm beyond their supports where 38 mm by 184 mm joists are used and not more than 600 mm beyond their supports where 38 mm by 235 mm or larger joists are used.
There is some criteria the joists must meet according o the 2012 international residential building codes.
Maximum end notches for 2 x 8 2 x 10 and 2 x 12 respectively are 1 13 16 2 5 16 and 2 13 16.
Floor cantilevers supporting an exterior balcony are permitted to be constructed in accordance with table r502 3 3 2.
You must use at least five framing nails to attach the rim joist to the ends of your joists.
The joist must have a minimum of 1 1 2 riding on the wall or beam.
The icc replaced the cantilever portion of the table in the 2018 irc with a maximum overhang length making the table similar to that in dca6.
Floor cantilevers constructed in accordance with table r502 3 3 1 shall be permitted where supporting a light frame bearing wall and roof only.
A southern pine 2 2x12 beam can span 8 feet when supporting joists spanning a maximum of 14 feet and it can cantilever 2 feet beyond the posts on each side.
2 the cantilevered portions referred to in sentence 1 shall not.
The cantilever portion of the 2015 irc joist span table is awkward to use.
If the joists are lapped then they must be lapped at least 3.
Floor cantilever spans shall not exceed the nominal depth of the wood floor joist.
Additional support for the floor joists is achieved by nailing the ends of the joists into headers.
Many building departments limit joist cantilevers to 24 maximum.
A full depth rim joist shall be provided at the unsupported end of the cantilever joists.
Building codes determine the maximum permissible cantilever span based on the size and species of lumber used for the floor joists.
Use either the 2018 irc deck joist span table or the joist span table in dca6 to size joists and cantilevers.
See section r301 2 2 2 5 item 1 for additional limitations on cantilevered floor joists for detached one and two family dwellings in seismic design category d 0 d 1 or d 2 and townhouses in seismic design category c d 0 d 1 or d 2.